These Granville-Phillips® vacuum gauges are ideal for applications where controller size and local control are critically important. 3 Overpressure Conditions Series 275 instruments are furnished calibrated for N2 They also measure the pressure of air correctly within the accuracy of the instrument. The high accuracy of the Granville Phillips 275 Convectron vacuum gauge sensor and repeatablilty help insure that processes start at the desired pressure time-after-time. Similarly, the user will require the Duniway gauge cable CEP-CBL-2-10 to connect the MKS / HPS Series 317 gauges or equivalent pressure gauges to the control unit.

275 Convectron® Pirani Vacuum Gauges have been the world-standard convection-enhanced Pirani gauge for over 35 years and are used in thousands of vacuum processes to accurately measure pressure from atmosphere to 10 -4 Torr. The MKS Granville Phillips 275 mini convectron module gauge, basic version, comes with one built-in adjustable set point pressure reading and a vacuum connection of 1/4 inch VCR-type female fitting. Page 1Series 275 ® ® Granville-Phillips Series 275 Mini-Convectron Vacuum Gauge Module with Linear Analog Output Instruction Manual Instruction Manual Instruction manual part number 275539 Revision G - November. Series 275 Convectron Gauge Bridge Amp PC Board7 Instruction Manual. This manual is for use only with the following catalog numbers: The “” symbol represents a variable in the catalog number. For assistance in using or servicing this instrument contact:. Lesker Company (KJLC) 275 is a convection-enhancedPirani vacuum gauge sensor that interfaces with external controllers such as the KJL375 series controller. Terranova® 906A back view.

With proper precautions, the Convectron Gauge may be used for pressure measurement of certain other gases. The “” symbol represents a variable in the catalog number. controller instruction manuals and are included in the series 475 convectron gauge controller.

A list of applicable catalog numbers is provided on the following page. Convectron Gauges are normally factory calibrated for N2 (air has approximately the same calibration). Granville-Phillips® Series 275 Mini-Convectron® Vacuum Gauge Module with Nonlinear Analog Outputs and Process Control Relays Instruction manual part number 275512 Revision 03 - June. They are capable of measuring from atmosphere to 1x10 -4 Torr and are available with analog output, RS485 interface, and DeviceNet interface. Absolute pressure measurement from atmosphere to 10 -4 Torr. Series 475 Convectron Gauge Controller Instruction ManualSuppliers of pressure relief valves and pr essure relief disks can be located via an online search, and are listed on 275 convectron gauge manual ThomasNet. Page 3 Instruction Manual © MKS Instruments, Inc. Do not attempt to use a Series 275 Gauge calibrated for N 2 to measure or control.

Convectron Gauge Technology With over 20 years of successful field installations, the Granville-Phillips Convectron® Gauge has become an industry standard. This Instruction Manual is for use with Granville-Phillips Series 275 Convectron Modules with DeviceNet, catalog numbers 275553. convection gauge compatibility InstruTech CVG101 Worker Bee™or Granville-Phillips® 275 Convectron® CE compliance EMC Directive /30/EU, EN55011, EN, EN, EN61326-1, EN61010-1 environmental RoHS 1. 3 Dimensions fitting dimension A NW16KF 1. Page 1 Series 275 ® Granville-Phillips Series 275 ® Mini-Convectron Vacuum Gauge Module with Nonlinear Analog Outputs and Process Control Relays Instruction Manual Instruction manual part number 275512 Revision D - November. : Description : Mini-Convectron Gauge/KF : Other Information : Flange: KF16 One Setpoint process relay Operating voltage 11.

3 Overpressure Series 275 instruments are furnished calibrated for N 2. This User Manual is intended to be used with the 275i displaying pressure in bar / mbar units of measure. unit labeled SENSORS to connect the pressure gauge cable (See Figure 2). Wide range vacuum pressure measurement from atmosphere to 1x10-4 Torr Individually calibrated gauges assure the highest measurement performance Easy installation in space-restricted.

4 Mini-Convectron®Module with RS-485 and Dual Process Relays Instruction Manual 1. Instruction Manual Series 275 This Instruction Manual is for use with Granville-Phillips Series 275 Convectron Modules with DeviceNet, catalog numbers 275553. Chapter 1 Granville-Phillips Mini-Convectron Module ® ® with RS-485 and Dual Process Relays Catalog numbers for Series 275 Mini-Convectron Modules This manual is for use only with the following catalog numbers:–EU 275507–EU 275527–EU 275528–EU 275529–EU 275530–EU 275531–EU 275532–EU 275533–EU 275534–EU 275535–EU. The Convectron® gauge is a convection-enhanced Pirani design 275 convectron gauge manual vacuum gauge that features individually calibrated gauges, temperature compensation 275 convectron gauge manual and convection technology for increased accuracy and repeatable vacuum measurements over seven decades from 1x10-4 Torr (1x10-4 mbar; 1 x10-2 Pa) to Atmosphere. The 275 is also a direct drop-in replacement pin-pin compatible gauge for the MKS Instruments / Granville-Phillips® 275 Convectron® gauge.

1Granville-Phillips Convectron® Vacuum Measurement System Installation, Operation, and Maintenance Instructions Instruction Manual Catalog No. Mini-Convectron®Vacuum Gauge Module with DeviceNetTMDigital Interface. Series 275 © MKS Instruments, Inc. They also measure the pressure of air correctly within the accuracy of the instrument. Ordering Information Convectron gauges with gold-plated tungsten sensor* Catalog 1/8 nPt / 1/2 inch tubulation/4 inch VCR®emaletype f fitting 275185. / Granville-Phillips® 275 Convectron® gauge.

com for additional configurations. Granville-Phillips® Mini-Convectron ® Module with Differential Amplifier Output Series 275 Instruction Manual For Customer Service or Technical Support 24 hours per day, 7 days per week, every day of the year including holidays:. Confirm that these safety devices are properly installed. These gauge tubes and controllers are ideal for new applications or as low-cost drop-in replacements to the Convectron ® brand of MKS / Granville-Phillips ® gauges. Convectron ®, Mini-Convectron. The 275 Convectron® Pirani Vacuum Gauge delivers fast response time - in milliseconds - compared to thermocouple-type gauges that respond in seconds. by a Convectron Gauge depends on the type of gas, the orientation of the gauge axis, and on the gas density in the gauge. This manual is for use only with Series 275 Convectron Vacuum Gauges with the following part numbers:.

Instruments / Granville-Phillips® 375 controller, 275 Convectron® gauge and gauge cable (Remote interface, relay and power connectors are different). 5-16VDC Range: 1 mTorr to 1000 torr for N2 Temperture range: +4°C to +50°C Bakeout: 85°C max with electronics attached; 150°C max with electronics removed Power supply and cables not included Series 275 Instruction Manual This Instruction Manual is for use with all Granville-Phillips Series 275 Mini-Convectron Vacuum Gauge Modules With Nonlinear Analog Outputs and Process Contro l Relays. The 1/8-DIN housing can be used as a bench top, or mounted in a cutout in an instrument panel. 275 Mini-Convectron® Modules with Analog Output or RS-485 Interface Author: MKS Instruments Subject: Features, benefits, and specifications for the MKS Instruments, Granville-Phillips® 275 Mini-Convectron® Modules with Analog Output or RS-485 Interface Keywords: 275 Mini Convectron Gauge Created Date: 10:39:59 AM.

Features: Wide measuring range: 10 -4 Torr to 1,000 Torr (10 -4 to 1,333 mbar). Overview 475 Convectron® Vacuum Gauge Controllers combine with the industry-standard Series 275 Convectron® gauge to provide high performance vacuum pressure measurement using a unique variation of thermal conductivity. It is a unique variation of thermal conductivity gauges where pressure measurement is based on the rate of heat loss from a sensor wire. Various analog output scaling provide signal compatibility with GP controller series 375, 475, the original GP 1/ Analog Convectron Gauge Controller as well as the Mini-Convectron® module. Granville-Phillips® Series 375 Convectron® Vacuum Gauge Controller Catalog numbers for Series 375 Convectron Vacuum Gauge Controllers 1/8 DIN, panel mount with digital display Operating Power: 12 to 24 Vdc This Instruction Manual is for use with the following catalog numbers.

The CVG101 is also a direct drop-in replacement pin-pin compatible gauge for the MKS Instruments / Granville-Phillips® 275 Convectron® gauge. The 275 series combines the industry-standard Convectron® gauge with electronics in a compact, modular design. The Granville-Phillips® 475 Convectron® Vacuum Gauge Controller combines with the industry-standard Series 275 Convectron® gauge to provide high performance vacuum pressure measurement using a unique variation of thermal conductivity. The sensor connector has the same pinouts and signal as the corresponding Convectron®. The VGC301 vacuum gauge controller is a convenient and inexpensive power supply and readout instrument for the InstruTech® CVG101 Worker Bee™ convection-enhanced Pirani vacuum gauge sensor or a Granville-Phillips® 275 Convectron®. User will require the Duniway gauge cable 275-CBL-2-10 to 275 convectron gauge manual connect the Granville-Phillips 275 Convectron® gauges and equivalent pressure gauges to the control unit. User will require the Duniway gauge cable 275-CBL-1-10 to connect the Granville-Phillips 275 Convectron® and equivalent gauges or the Duniway gauge cable CEP-CBL-1-10 to connect the MKS / HPS Series 317 gauge to the control unit.

This gauge measures vacuum pressure from atmosphere to 1x10-4 Torr and are ideal for roughing and foreline pressure measurement. Please see 275 Mini-Convectron® Transducers on mksinst. com under “Relief Valves” and “Rupture Discs. The 275 is also a direct drop-in replacement pin-pin compatible gauge for the Brooks Automation, Inc. note 2: convectron gauges are not intended for use with flammable or explosive gases. Granville-Phillips® Mini-Convectron® Vacuum Gauge Module with.

The InstruTech® CVG101 Worker Bee™ is a convection-enhanced Pirani vacuum gauge sensor that interfaces with external controllers such as the InstruTech VGC301 controller. This Instruction Manual is for use with all Granville-Phillips Series 275 Mini-Convectron Vacuum Gauge Modules With Nonlinear Analog Outputs and Process Contro l Relays. A list of catalog numbers for the entire module and replacement gauges is provided on the following page.

275 convectron gauge manual

email: zoxoturi@gmail.com - phone:(453) 599-9537 x 9854

Manual oregon scientific se232 em portugues - Servico manual

-> Plush bus service manual
-> Perdi o manual do meu conversor gratuito

275 convectron gauge manual - Programming manual


Sitemap 1

One touch mini owners manual - Owners chrysler town country